gsw_CT_from_pt
Conservative Temperature from potential temperature
Contents
USAGE:
CT = gsw_CT_from_pt(SA,pt)
DESCRIPTION:
Calculates Conservative Temperature of seawater from potential
temperature (whose reference sea pressure is zero dbar).
INPUT:
SA = Absolute Salinity [ g/kg ]
pt = potential temperature (ITS-90) [ deg C ]
SA & pt need to have the same dimensions.
OUTPUT:
CT = Conservative Temperature [ deg C ]
EXAMPLE:
SA = [34.7118; 34.8915; 35.0256; 34.8472; 34.7366; 34.7324;]
pt = [28.7832; 28.4209; 22.7850; 10.2305; 6.8292; 4.3245;]
CT = gsw_CT_from_pt(SA,pt)
CT =
28.809923015982083
28.439144260767169
22.786246608464264
10.226165605435785
6.827183417643142
4.323565182322069
AUTHOR:
David Jackett, Trevor McDougall and Paul Barker [ help@teos-10.org ]
VERSION NUMBER:
3.04 (10th December, 2013)
REFERENCES:
IOC, SCOR and IAPSO, 2010: The international thermodynamic equation of
seawater - 2010: Calculation and use of thermodynamic properties.
Intergovernmental Oceanographic Commission, Manuals and Guides No. 56,
UNESCO (English), 196 pp. Available from the TEOS-10 web site.
See section 3.3 of this TEOS-10 Manual.
The software is available from http://www.TEOS-10.org